Battery Distribution Bays
Battery Distribution Bay Protect your power infrastructure with Westell/Noran Tel Battery Distribution Bays intended for primary protection applications. These expandable bays can distribute up to 1000A per bus with optional ammeters available for monitoring capacity utilization. Available in heights from 7’ up to 11’6” with standard 23” mounting flanges. Up to 5 panels can be installed using AM or CD breaker types. Alternatively, TPS fuse style over-current protection is available. Benefits - Primary over-current protection
Features Standard Battery Distribution Bay - Available in 7'-0", 8'0", 9'0" and 11'6" racks with 23" mounting
- Upper extension bars available
- Expandable to 5 panels (not applicable to all configurations)
- AM Breakers, CD breakers and TPS fuse panel applications all available
- Up to 1000Amp/bus capability
- Optional Meter panels available
- Bays can be supplied with an internal return panel
- Dry Form C contacts are provided on each panel to extend alarms
Features Mini Fused Distribution Bay - Typically shipped without a rack but can be shipped in any stadard 23" rack (7'-0", 8'0", 9'0" and 11'6" racks available)
- Dual bus with 8 to 16 TPS fuse holders per bus
- Field expandable from 1 to 2 fuse panels (16-32 fuses)
- 2 and 4 bus configurations available
- Up to 600Amp/bus capability
- Equipped with Volt and Amp meters
- Optional internal return bars available
- Dry Form C contacts are provided for each bus to extend alarms
Add'l Options Standard Bay Extension Panels
BDB Compatible Breaker Panels
-
| Breaker Type |
CD (1 to 100Amps) |
| Breaker Positions |
12 CD Breakers/Panel, 6 CD Breakers/Bus (dual bus) |
| Current Rating |
800 Amps/Panel, 400 Amps/Bus |
| Voltage |
-24 or -48 Vdc Typical (see manual for more info) |
| Input |
Two 3/8" holes on 1" centers (each bus) |
| Output |
Two 3/8" PEM nuts on 1" centers for each breaker position |
| Alarm Connection |
wire wrap pin |
| Rack Mounting |
19" Racks, 1-3/4" panel spacing (5 RU, 8.75"H) |
| Application |
BDFB |
Downloads:
-
(19", 8/8 version of panel shown in picture)
| Breaker Type |
CD (1 to 100Amps) |
| Breaker Positions |
16 CD Breakers/Panel, 8 CD Breakers/Bus (dual bus) |
| Current Rating |
800 Amps/Panel, 400 Amps/Bus |
| Voltage |
-24 or -48 Vdc Typical |
| Input |
Two 3/8" holes on 1" centers (each bus) |
| Output |
Two 3/8" PEM nuts on 1" centers for each breaker position |
| Alarm Connection |
wire wrap pin |
| Rack Mounting |
23" Racks, 1-3/4" panel spacing (5 RU, 8.75"H) |
| Application |
BDFB |
Downloads:
-
| Breaker Type |
AM (.1 to 100Amps) |
| Breaker Positions |
16 AM Breakers/Panel, 8 AM Breakers/Bus (dual bus) |
| Current Rating |
400 Amps/Panel, 200 Amps/Bus |
| Voltage |
-24 or -48 Vdc Typical |
| Input |
Two 3/8" holes on 1" centers (each bus) |
| Output |
Two 1/4" holes on 5/8" centers for each breaker position |
| Alarm Connection |
wire wrap pin |
| Rack Mounting |
19" Racks, 1-3/4" panel spacing (4 RU, 7"H) |
| Application |
BDFB |
Downloads:
-
| Breaker Type |
AM (.1 to 100Amps) |
| Breaker Positions |
20 AM Breakers/Panel, 10 AM Breakers/Bus (dual bus) |
| Current Rating |
800 Amps/Panel, 400 Amps/Bus |
| Voltage |
-24 or -48 Vdc Typical |
| Input |
Two 3/8" holes on 1" centers (each bus) |
| Output |
Two 1/4" holes on 5/8" centers for each breaker position |
| Alarm Connection |
wire wrap pin |
| Rack Mounting |
23" Racks, 1-3/4" panel spacing (4 RU, 7"H) |
| Application |
BDFB |
Downloads:
|
|