Standard GMT Panels Protect your power infrastructure with Westell/Noran Tel GMT Fuse Panels intended for secondary protection applications. With fuse counts from 5 to 20 per bus, alarm contacts, and individual fuse capacities up to 20A, Westell OSPlant has the panel for your particular requirements. Benefits - Peace of mind knowing your network is protected
- Full monitoring of blown fuses and loss of bus power in every panel
- Industry standard configurations
- Dual-bus designs for power redundancy
- Quick Delivery for standard configurations
Features - Polarity insensitive circuitry
- Dual voltage panels (24 or 48Vdc batteries)
- High capacity 1/4" stud input blocks
- Offset output blocks
- Cable tie bars
- Spare fuse holders (GMT)
- Full rear lexan shield
- Fuse and input power fail alarms
- NEBS approved
Standard GMT Panels
-
| Fuse Type |
GMT (18/100 to 20 Amps) |
| Fuse Positions |
30 GMT/Panel, 15 GMT/Bus (dual bus) |
| Current Rating |
200 Amps/Panel, 100 Amps/Bus |
| Voltage |
-24 or -48 Vdc Typical, 22 to 58 Vdc Max. Polarity Insensitive (+/- Bat) |
| Input Block |
Two 1/4" studs on 5/8" centers |
| Output Block |
#6 screw terminal |
| Alarm Connection |
.045" sq wire wrap pin |
| Rack Mounting |
19"/23" Racks, 1" or 1-3/4" panel spacing (1 RU, 1-3/4"H) |
| Approvals |
NEBS level 3 certified, zone 4 earthquake |
Downloads:
-

| Fuse Type |
GMT (18/100 to 20 Amps) |
| Fuse Positions |
20 GMT/Panel, 10 GMT/Bus (dual bus) |
| Current Rating |
200 Amps/Panel, 100 Amps/Bus |
| Voltage |
-24 or -48 Vdc Typical, 22 to 58 Vdc Max. Polarity Insensitive (+/- Bat) |
| Input Block |
Two 1/4" studs on 5/8" centers |
| Output Block |
#6 screw terminal |
| Alarm Connection |
.045" sq wire wrap pin |
| Rack Mounting |
19"/23" Racks, 1" or 1-3/4" panel spacing (1 RU, 1-3/4"H) |
| Approvals |
NEBS level 3 certified, zone 4 earthquake |
Downloads:
-
| Fuse Type |
GMT (18/100 to 15 Amps) |
| Fuse Positions |
8 GMT/Panel, 4 GMT/Bus (dual bus) |
| Current Rating |
120 Amps/Panel, 60 Amps/Bus |
| Voltage |
-24 or -48 Vdc Typical, 22 to 58 Vdc Max. Polarity Insensitive (+/- Bat) |
| Input Block |
Two 1/4" studs on 5/8" centers |
| Output Block |
#6 screw terminal |
| Alarm Connection |
.045" sq wire wrap pin |
| Rack Mounting |
19"/23" Racks, 1" or 1-3/4" panel spacing (1 RU, 1-3/4"H) |
| Approvals |
NEBS level 3 certified, zone 4 earthquake |
Downloads:
-
| Fuse Type |
GMT (18/100 to 15 Amps) |
| Fuse Positions |
10 GMT/Panel, 5 GMT/Bus (dual bus) |
| Current Rating |
150 Amps/Panel, 75 Amps/Bus |
| Voltage |
-24 or -48 Vdc Typical, 22 to 58 Vdc Max. Polarity Insensitive (+/- Bat) |
| Input Block |
Two 1/4" studs on 5/8" centers |
| Output Block |
#6 screw terminal |
| Alarm Connection |
.045" sq wire wrap pin |
| Rack Mounting |
19"/23" Racks, 1" or 1-3/4" panel spacing (1 RU, 1-3/4"H) |
| Approvals |
NEBS level 3 certified, zone 4 earthquake |
Downloads:
-
| Fuse Type |
GMT (18/100 to 15 Amps) |
| Fuse Positions |
10 GMT/Panel, 5 GMT/Bus (dual bus) |
| Current Rating |
100 Amps/Panel, 50 Amps/Bus |
| Voltage |
-24 or -48 Vdc Typical, 22 to 58 Vdc Max. Polarity Insensitive (+/- Bat) |
| Input Block |
Two 1/4" studs on 5/8" centers, Front Access |
| Output Block |
#6 screw terminal, Front Access |
| Alarm Connection |
.045" sq wire wrap pin, Front Access |
| Rack Mounting |
19"/23" Racks, 1" or 1-3/4" panel spacing (1 RU, 1-3/4"H) |
| Approvals |
NEBS level 3 certified, zone 4 earthquake |
Downloads:
-
| Fuse Type |
GMT (18/100 to 20 Amps) |
| Fuse Positions |
10 GMT/Panel, 5 GMT/Bus (dual bus) |
| Current Rating |
200 Amps/Panel, 100 Amps/Bus |
| Voltage |
-24 or -48 Vdc Typical, 22 to 58 Vdc Max. Polarity Insensitive (+/- Bat) |
| Input Block |
Two 1/4" studs on 5/8" centers |
| Output Block |
#6 screw terminal |
| Alarm Connection |
.045" sq wire wrap pin |
| Rack Mounting |
19"/23" Racks, 1" or 1-3/4" panel spacing (1 RU, 1-3/4"H) |
| Approvals |
NEBS level 3 certified, zone 4 earthquake |
| Features |
Uses special GMT fuseholder that will accept up to 20 Amps |
Downloads:
-

| Fuse Type |
GMT (18/100 to 15 Amps) |
| Fuse Positions |
20 GMT/Panel, 10 GMT/Bus (dual bus) |
| Current Rating |
200 Amps/Panel, 100 Amps/Bus |
| Voltage |
-24 or -48 Vdc Typical, 22 to 58 Vdc Max. Polarity Insensitive (+/- Bat) |
| Input Block |
Two 1/4" studs on 5/8" centers |
| Output Block |
#6 screw terminal |
| Alarm Connection |
.045" sq wire wrap pin |
| Rack Mounting |
19"/23" Racks, 1" or 1-3/4" panel spacing (1 RU, 1-3/4"H) |
| Approvals |
NEBS level 3 certified, zone 4 earthquake |
Downloads:
-

| Fuse Type |
GMT (18/100 to 15 Amps) |
| Fuse Positions |
20 GMT/Panel, 10 GMT/Bus (dual bus) |
| Current Rating |
200 Amps/Panel, 100 Amps/Bus |
| Voltage |
-24 or -48 Vdc Typical, 22 to 58 Vdc Max. Polarity Insensitive (+/- Bat) |
| Input Block |
Two 1/4" studs on 5/8" centers |
| Output Block |
#6 screw terminal |
| Alarm Connection |
.045" sq wire wrap pin |
| Rack Mounting |
19"/23" Racks, 1" or 1-3/4" panel spacing (1 RU, 1-3/4"H) |
| Approvals |
NEBS level 3 certified, zone 4 earthquake |
| Features |
Full front access |
Downloads:
-
| Fuse Type |
GMT (18/100 to 20 Amps) |
| Fuse Positions |
20 GMT/Panel, 10 GMT/Bus (dual bus) |
| Current Rating |
200 Amps/Panel, 100 Amps/Bus |
| Voltage |
-24 or -48 Vdc Typical, 22 to 58 Vdc Max. Polarity Insensitive (+/- Bat) |
| Input Block |
Two 1/4" studs on 5/8" centers |
| Output Block |
#6 screw terminal |
| Alarm Connection |
.045" sq wire wrap pin |
| Rack Mounting |
19"/23" Racks, 1" or 1-3/4" panel spacing (1 RU, 1-3/4"H) |
| Approvals |
NEBS level 3 certified, zone 4 earthquake |
Downloads:
-

| Fuse Type |
GMT (18/100 to 15 Amps) |
| Fuse Positions |
24 GMT/Panel, 12 GMT/Bus (dual bus) |
| Current Rating |
200 Amps/Panel, 100 Amps/Bus |
| Voltage |
-24 or -48 Vdc Typical, 22 to 58 Vdc Max. Polarity Insensitive (+/- Bat) |
| Input Block |
Two 1/4" studs on 5/8" centers |
| Output Block |
#6 screw terminal |
| Alarm Connection |
.045" sq wire wrap pin |
| Rack Mounting |
19"/23" Racks, 1" or 1-3/4" panel spacing (1 RU, 1-3/4"H) |
| Approvals |
NEBS level 3 certified, zone 4 earthquake |
Downloads:
-
| Fuse Type |
GMT (18/100 to 15 Amps) |
| Fuse Positions |
40 GMT/Panel, 20 GMT/Bus (dual bus) |
| Current Rating |
200 Amps/Panel, 100 Amps/Bus |
| Voltage |
-24 or -48 Vdc Typical, 22 to 58 Vdc Max. Polarity Insensitive (+/- Bat) |
| Input Block |
Two 1/4" studs on 5/8" centers |
| Output Block |
#6 screw terminal |
| Alarm Connection |
.045" sq wire wrap pin |
| Rack Mounting |
23" Racks, 1" or 1-3/4" panel spacing (1 RU, 1-3/4"H) |
| Approvals |
NEBS level 3 certified, zone 4 earthquake |
Downloads:
-
| Fuse Type |
GMT (18/100 to 15 Amps) |
| Fuse Positions |
40 GMT/Panel, 20 GMT/Bus (dual bus) |
| Current Rating |
200 Amps/Panel, 100 Amps/Bus |
| Voltage |
-24 or -48 Vdc Typical, 22 to 58 Vdc Max. |
| Input Block |
Two 1/4" studs on 5/8" centers |
| Output Block |
Mechanical elevator clamp |
| Alarm Connection |
Mechanical elevator clamp |
| Rack Mounting |
19"/23" Racks, 1" or 1-3/4" panel spacing (1 RU, 1-3/4"H) |
| Approvals |
NEBS level 3 certified, zone 4 earthquake |
Downloads:
-
| Fuse Type |
GMT (18/100 to 15 Amps) |
| Fuse Positions |
20 GMT/Panel, Single Bus |
| Current Rating |
100 Amps |
| Voltage |
-24 or -48 Vdc Typical, 22 to 58 Vdc Max. Polarity Insensitive (+/- Bat) |
| Input Block |
Two 1/4" studs on 5/8" centers |
| Output Block |
#6 screw terminal |
| Alarm Connection |
.045" sq wire wrap pin |
| Rack Mounting |
19"/23" Racks, 1" or 1-3/4" panel spacing (1 RU, 1-3/4"H) |
| Approvals |
NEBS level 3 certified, zone 4 earthquake |